PUREPEROX™ PLATFORM

On-Site Hydrogen Peroxide Concentrationup to 96% w/w

Value Proposition

Concentration That Fits Your Process

Match the process scope to your feed, production demand and commercial requirements.

01.

Stage selection

Enter later stages with higher-concentration feeds to reduce equipment scope, time and utility demand.

02.

Supply flexibility

Concentrate accepted aqueous feed locally to your required strength and reduce delivery lock-in.

03.

Inventory alignment

Schedule concentration around production demand and size buffers for peak resilience.

04.

Full cost clarity

Compare cost per kilogram of usable finished product at the required concentration and quality.

05.

Capacity pathway

Assess PP152 and PP154 today, then scale toward PP156 and industrial plants through defined programmes.

Product-Family Comparison

Choose Your Capacity. Define Your Configuration.

Select the pathway that fits your feed concentration, product target and daily production demand.

  • Batch vacuum concentration
  • Continuous vacuum concentration
  • Controlled operating conditions

PP152 and PP154 are available equipment platforms. PP156 and industrial plants are development pathways.

Developed & tested01.

PP152

Compact Platform

Platform capacity8 kg/dayFinished product solution mass, on the documented duty and operating basis.

Intended role

Compact on-site concentration for applications within the documented PP152 operating envelope.

Validation / status

Developed and tested. CE marked for the assessed configuration.

Concentration capability · % w/w

Feed: 5%Product: up to 96%

The selected duty determines the required stages and applicable output.

Commercial data available02.

PP154

Higher-Capacity Platform

Platform capacity20 kg/dayFinished product solution mass, on the documented duty and operating basis.

Intended role

Higher-capacity concentration for production requirements beyond the compact pathway.

Validation / status

Commercial data available. Conformity status and applicable scope are identified in supply documentation.

Concentration capability · % w/w

Feed: 5%Product: up to 96%

Configuration and performance are confirmed against the selected concentration duty.

Planned development03.

PP156

Planned Scale-Up Platform

Development target100 kg/day targetFinished product solution mass; development objective, not a demonstrated rating.

Intended role

Planned higher-output system for the next capacity step in the PurePerox™ family.

Validation / status

Simulation-supported development. Not yet built; physical performance validation and conformity assessment remain outstanding.

Planned concentration capability · % w/w

Planned feed: 5%Planned product: up to 96%

The operating envelope will be established through engineering and physical validation.

Future pathway04.

Industrial Plants

Future Industrial Platform

Production requirementProject-definedFeasibility-led requirement; capacity is not established.

Intended role

Future larger-capacity plants for industrial facilities and process integration.

Validation / status

Future development pathway. No industrial-scale equipment, simulation or performance data are currently available.

Concentration requirement · % w/w

Tonne-per-day requirementsApplication-defined target

Capacity, plant architecture, quality and operating envelope require project-specific feasibility, engineering and validation.

Capacity & Performance Basis

All capacities refer to finished product solution mass, rather than volume or 100% H2O2-equivalent mass. Output depends on feed and product concentration, installed stages, complete cycle time and operating hours. Concentration capability does not establish identical throughput at every endpoint or a specialised purity grade.

Development Basis

PP156 and industrial plants require an agreed, funded development programme. Industrial discussions are preliminary; performance guarantees, plant architecture, operating mode, delivery schedule and EPC or turnkey scope have not been established.

Read the power and energy basis
kW

Electrical power

Installed, operating or peak electrical demand, with the basis identified. Connected power does not establish actual energy consumption.

kWh/kg

Specific energy

Energy per kilogram of finished product solution at the specified concentration. Depends on feed, selected stages, output, operating conditions and equipment duty.

Volumetric output in L/day is derived from finished solution mass using density at the applicable concentration and temperature.

Operating Principle

Staged Concentration. Controlled Operation.

PurePerox™ removes water from aqueous hydrogen peroxide through a staged vacuum concentration process. S1 and S2 operate in batch mode; S3 and S4 operate continuously.

01Batch concentration · S1–S202Continuous concentration · S3–S4
S1Batch

Initial Concentration

Batch vacuum concentration

5% or 10%approximately 30%

Pre-concentrates accepted dilute aqueous feed for intermediate processing.

S2Batch

Intermediate Concentration

Batch vacuum concentration

Approximately 30%50%

Increases intermediate-strength concentration. Suitable 30% feed may enter directly.

S3Continuous

Higher-Concentration Processing

Continuous vacuum concentration

50%75%

Further water removal; feed rate, output and peroxide recovery are confirmed for the selected duty.

S4Continuous

Final High-Strength Concentration

Continuous vacuum concentration

90%+ target · Up to 96%

Accepts suitable higher-concentration feed. Exact endpoint and tolerance form part of the product specification.

Representative duties · All concentrations % w/w · Not every application requires all four stages.

Stage Integration

Where batch stages supply continuous stages, engineering addresses intermediate buffering, transfer sequencing and stage-capacity matching.

Stream Management

The material balance accounts for product, off-gas, condensate, residual hold-up and samples. Vapour or droplet entrainment determines the required recovery and handling arrangements.

Monitoring & Protective Functions

Engineering review addresses materials compatibility, contamination, temperature and vacuum control, oxygen release, abnormal conditions and utility interruption. Installed monitoring and protective functions are documented for the supplied configuration.

Concentration figures are representative duties or configuration-dependent targets. Feed suitability, exact endpoint and tolerance, peroxide recovery and achievable output require confirmation for the selected application.

Research Heritage & Engineering Innovation

Research Heritage. Engineering Progress.

PurePerox™ draws on hydrogen peroxide concentration research and engineering experience contributed by Dr. B.V.S. Jyoti, HYEMETA’s Chief Technical Advisor and a named co-inventor on earlier patent filings in this field.

HYEMETA develops PurePerox™ through its own equipment engineering, automation, process integration and testing—turning technical experience into modular concentration systems configured for specific application requirements.

01Research Heritage
Earlier research in simplified in-situ hydrogen peroxide concentration.
02Inventor Expertise
Dr. B.V.S. Jyoti, Chief Technical Advisor and named co-inventor on the earlier patent family.
03Historical Filing References
Netherlands: NL204229B1 · United States: application 17/775,065.
04Platform Architecture
Application-specific batch and continuous vacuum concentration stages.
05Developed Systems
PP152: developed and tested; CE marked for the assessed configuration. PP154: commercial operating data available.
06Scale-Up Roadmap
PP156: simulation-supported development targeting 100 kg/day; physical validation outstanding. Industrial plants: future development pathway.

Engineering contribution

HYEMETA’s Engineering Contribution

Equipment design, automated process control, fluid handling and stage integration support a continuing programme of process optimisation, operating repeatability and progressive capacity scale-up.

Historical filing references identify research heritage; they do not assert HYEMETA’s ownership of earlier patent rights or establish current patent protection for PurePerox™.

Industrial Applications & Concentration Pathways

All concentrations: % w/w

Your Application. A Defined Concentration Pathway.

Batch and continuous vacuum concentration stages, configured for application-specific duties from 5% to 96% w/w.

[01]

Specialist High-Strength Peroxide & HTP

  • Aerospace
  • Space systems
  • Propulsion R&D
Target90%+, with endpoints up to 96% w/w subject to confirmation
StagesS2 + S3 + S4, S3 + S4 or S4
ModeBatch + Continuous or Continuous

Representative routes

  • 30%90%+S2 + S3 + S4Batch + Continuous

    Stage sequence: 30% → 50% → 75% → 90%+

  • 50%90%+S3 + S4Continuous

    Stage sequence: 50% → 75% → 90%+

  • 75%90%+S4Continuous

Consider on-site concentration for propulsion testing and specialist oxidiser development where transport availability, high-strength supply or inventory requirements affect operations. Exact endpoints and tolerances are confirmed against the selected operating envelope.

Why concentration matters

Reducing the water fraction changes the energy released per kilogram during catalytic decomposition; the endpoint must be matched to the propulsion system.

Application chemistry

Chemical role: In qualified propulsion systems, hydrogen peroxide can act as a monopropellant or oxidiser. Catalytic decomposition releases heat and produces water and oxygen: 2 H2O2 → 2 H2O + O2.

Configuration & Quality Basis

Routes provide preliminary selection guidance. Final configuration depends on feed acceptance, exact concentration and tolerance, stage compatibility, peroxide recovery, utilities and required finished product output.

Concentration is distinct from purity grade. Producing peroxide up to 96% w/w does not automatically establish electronic, pharmaceutical, food-contact or propellant grade.

Define Your Process Requirement

Share your feed concentration, product specification and production demand. HYEMETA’s application-engineering team will review your requirements and recommend the appropriate next technical step.

Requirements still being defined? Select “Assessing feasibility” or “Discuss the application first” in the enquiry form.

Request an Application Review
Technical reference — propulsion chemistry

This reference describes hydrogen peroxide chemistry; it does not validate PurePerox equipment performance or product-grade suitability.