Stage selection
Enter later stages with higher-concentration feeds to reduce equipment scope, time and utility demand.
PUREPEROX™ PLATFORM
Match the process scope to your feed, production demand and commercial requirements.
Enter later stages with higher-concentration feeds to reduce equipment scope, time and utility demand.
Concentrate accepted aqueous feed locally to your required strength and reduce delivery lock-in.
Schedule concentration around production demand and size buffers for peak resilience.
Compare cost per kilogram of usable finished product at the required concentration and quality.
Assess PP152 and PP154 today, then scale toward PP156 and industrial plants through defined programmes.
Select the pathway that fits your feed concentration, product target and daily production demand.
PP152 and PP154 are available equipment platforms. PP156 and industrial plants are development pathways.
Compact Platform
Compact on-site concentration for applications within the documented PP152 operating envelope.
Developed and tested. CE marked for the assessed configuration.
The selected duty determines the required stages and applicable output.
Higher-Capacity Platform
Higher-capacity concentration for production requirements beyond the compact pathway.
Commercial data available. Conformity status and applicable scope are identified in supply documentation.
Configuration and performance are confirmed against the selected concentration duty.
Planned Scale-Up Platform
Planned higher-output system for the next capacity step in the PurePerox™ family.
Simulation-supported development. Not yet built; physical performance validation and conformity assessment remain outstanding.
The operating envelope will be established through engineering and physical validation.
Future Industrial Platform
Future larger-capacity plants for industrial facilities and process integration.
Future development pathway. No industrial-scale equipment, simulation or performance data are currently available.
Capacity, plant architecture, quality and operating envelope require project-specific feasibility, engineering and validation.
All capacities refer to finished product solution mass, rather than volume or 100% H2O2-equivalent mass. Output depends on feed and product concentration, installed stages, complete cycle time and operating hours. Concentration capability does not establish identical throughput at every endpoint or a specialised purity grade.
PP156 and industrial plants require an agreed, funded development programme. Industrial discussions are preliminary; performance guarantees, plant architecture, operating mode, delivery schedule and EPC or turnkey scope have not been established.
Installed, operating or peak electrical demand, with the basis identified. Connected power does not establish actual energy consumption.
Energy per kilogram of finished product solution at the specified concentration. Depends on feed, selected stages, output, operating conditions and equipment duty.
Volumetric output in L/day is derived from finished solution mass using density at the applicable concentration and temperature.
PurePerox™ removes water from aqueous hydrogen peroxide through a staged vacuum concentration process. S1 and S2 operate in batch mode; S3 and S4 operate continuously.
Batch vacuum concentration
5% or 10%approximately 30%Pre-concentrates accepted dilute aqueous feed for intermediate processing.
Batch vacuum concentration
Approximately 30%50%Increases intermediate-strength concentration. Suitable 30% feed may enter directly.
Continuous vacuum concentration
50%75%Further water removal; feed rate, output and peroxide recovery are confirmed for the selected duty.
Continuous vacuum concentration
90%+ target · Up to 96%Accepts suitable higher-concentration feed. Exact endpoint and tolerance form part of the product specification.
Representative duties · All concentrations % w/w · Not every application requires all four stages.
Where batch stages supply continuous stages, engineering addresses intermediate buffering, transfer sequencing and stage-capacity matching.
The material balance accounts for product, off-gas, condensate, residual hold-up and samples. Vapour or droplet entrainment determines the required recovery and handling arrangements.
Engineering review addresses materials compatibility, contamination, temperature and vacuum control, oxygen release, abnormal conditions and utility interruption. Installed monitoring and protective functions are documented for the supplied configuration.
Concentration figures are representative duties or configuration-dependent targets. Feed suitability, exact endpoint and tolerance, peroxide recovery and achievable output require confirmation for the selected application.
PurePerox™ draws on hydrogen peroxide concentration research and engineering experience contributed by Dr. B.V.S. Jyoti, HYEMETA’s Chief Technical Advisor and a named co-inventor on earlier patent filings in this field.
HYEMETA develops PurePerox™ through its own equipment engineering, automation, process integration and testing—turning technical experience into modular concentration systems configured for specific application requirements.
Engineering contribution
Equipment design, automated process control, fluid handling and stage integration support a continuing programme of process optimisation, operating repeatability and progressive capacity scale-up.
Historical filing references identify research heritage; they do not assert HYEMETA’s ownership of earlier patent rights or establish current patent protection for PurePerox™.
All concentrations: % w/w
Batch and continuous vacuum concentration stages, configured for application-specific duties from 5% to 96% w/w.
Stage sequence: 30% → 50% → 75% → 90%+
Stage sequence: 50% → 75% → 90%+
Consider on-site concentration for propulsion testing and specialist oxidiser development where transport availability, high-strength supply or inventory requirements affect operations. Exact endpoints and tolerances are confirmed against the selected operating envelope.
Reducing the water fraction changes the energy released per kilogram during catalytic decomposition; the endpoint must be matched to the propulsion system.
Chemical role: In qualified propulsion systems, hydrogen peroxide can act as a monopropellant or oxidiser. Catalytic decomposition releases heat and produces water and oxygen: 2 H2O2 → 2 H2O + O2.